A musculoskeletal model driven by dual Microsoft Kinect Sensor data

Reference Skals S, Rasmussen KP, Bendtsen KM, et al. A musculoskeletal model driven by dual Microsoft Kinect Sensor data. Multibody System Dynamics 2017;41(4):297-316.
Udgivet: 2017
[Type] Videnskabelig artikel
[Resumé] Musculoskeletal modeling is becoming a standard method to estimate muscle, ligament and joint forces non-invasively. As input, these models often use kinematic data obtained using marker-based motion capture, which, however, is associated with several limitations, such as soft tissue artefacts and the time-consuming task of attaching markers. These issues can potentially be addressed by applying marker-less motion capture. Therefore, we developed a musculoskeletal model driven by marker-less motion capture data, based on two Microsoft Kinect Sensors and iPi Motion Capture software, which incorporated a method for predicting ground reaction forces and moments. For validation, selected model outputs (e.g. ground reaction forces, joint reaction forces, joint angles and joint range-of-motion) were compared to musculoskeletal models driven by simultaneously recorded marker-based motion capture data from 10 males performing gait and shoulder abduction with and without external load. The primary findings were that the vertical ground reaction force during gait and the shoulder abduction/adduction angles, glenohumeral joint reaction forces and deltoideus forces during both shoulder abduction tasks showed comparable results. In addition, shoulder abduction/adduction range-of-motions were not significantly different between the two systems. However, the lower extremity joint angles, moments and reaction forces showed discrepancies during gait with correlations ranging from weak to strong, and for the majority of the variables, the marker-less system showed larger standard deviations. Although discrepancies between the systems were identified, the marker-less system shows potential, especially for tracking simple upper-body movements
Link: http://dx.doi.org/10.1007/s11044-017-9573-8
Bestilling: Denne udgivelse kan ikke bestilles fra NFA's Forlag
[Oprettet] 30.11.2017
 
Opdateret  30.11.2017
Kontakt: NFA's webredaktion
 
Sociale medieomtaler af denne artikel

Klik på cirklen for mere information om omtaler og deling af denne artikel.

Altmetric er en tjeneste, der registrerer sociale medieomtaler og delinger af referencer forskningsartikler, hvis læsere har linket unikt til artiklen (tidskriftets abstractside, DOI-link etc.). Tjenesten overvåger p.t. omtaler på udvalgte sociale medieplatforme.

Hvis cirklen viser "?", er der endnu ikke registreret omtaler på de overvågede medier.

Om betalingstidsskrifter
Mange videnskabelige tidsskrifter tager betaling for adgang til hele artiklen. Hvis du ikke har adgang til et bestemt tidsskrift, kan du benytte Bibliotek.dk. Her kan du søge efter artikler, bogtitler og tidsskrifter på tværs af de danske bibliotekssystemer.

Det letteste er at gå ind under "Flere søgemuligheder" på siden og så indtaste tidsskriftets navn i Feltet "Titel". Derved får du en oversigt over folke- eller forskningsbiblioteker, som abonnerer på det pågældende tidsskrift.

 
 
 

Det Nationale Forskningscenter for Arbejdsmiljø | Lersø Parkallé 105 | DK-2100 København Ø |

Tlf 39 16 52 00 | fax 39 16 52 01 | e-mail: nfa@arbejdsmiljoforskning.dk | CVR: 15413700 | EAN: 5798000399518

Vis desktop version
|WEBSITET ANVENDER COOKIES TIL AT HUSKE DIG OG DINE INDSTILLINGER.| Læs mere her